gfk 1504k manual

File Name:gfk 1504k manual.pdf
Size:3463 KB
Type:PDF, ePub, eBook, fb2, mobi, txt, doc, rtf, djvu
Category:Book
Uploaded20 May 2019, 13:33 PM
InterfaceEnglish
Rating4.6/5 from 844 votes
StatusAVAILABLE
Last checked11 Minutes ago!

gfk 1504k manual

PDF Supply is not an authorized distributor, reseller or representative of the products featured on this website. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to indicate any affiliation with or authorization by any rights holder. User's Manual The quantity you tried to add to your cart is unavailable. Go To Cart Close The products listed on this website may vary as to their country of origin; the accessories, and other items included with the product; and the language used on the packaging, the parts, and any related instructions or printed material related to the products. This website is not sanctioned or approved by any manufacturer or tradename listed. Designated trademarks, brand names and brands appearing herein are the property of their respective owners. Javascript and Cookies must be enabled to checkout.Our Website may contain our service marks or trademarks as well as those of our affiliates or other companies, in the form of words, graphics, and logos. Our Content, as found within our Website, Blogs and Services, is protected under United States and foreign copyrights. The copying, redistribution, use or publication by you of any such Content, is strictly prohibited. Your use of our Website and Services does not grant you any ownership rights to our Content. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to indicate any affiliation with or authorization by any rights holder. We can help you with your Revision specific needs. Free Ground delivery on all orders! Close This New product is sealed in the original manufacturer’s packaging with all sub-assemblies and documentation. May indicate older date code. Comes with a PDF Supply 3-year warranty.Product may ship in manufacturer or PDF Supply packaging. Includes a PDF Supply 3 Year Warranty.http://www.roxracing.eu/userfiles/bosch-gwh-260-pn-l-manual.xml

Our reconditioned units look NEW down to the paint, label and packaging. We include all documentation and subassemblies including keys, terminal blocks, and grounding cables. Reconditioned products from PDF Supply are a cost-effective alternative to new and obsoleted PLC products. Every part is reconditioned down to the circuit board level and updated to the latest revision. All parts are thoroughly inspected and hand-cleaned before being functionally tested in a fully configured system.It will meet all electrical and dimensional characteristics at a substantially reduced price. Free Ground delivery on all orders! Close If you find a legacy GE PLC part advertised for less on an authorized GE PLC distributor website, simply contact us and send us a link to the lower advertised price. We will match that price and ship overnight FREE. The item must be in stock, in similar condition and be able to ship same day. Close Some units may be unrepairable due to extensive damage or component obsolescence. In those cases, we promise to return your product promptly. Repairing your unit provides a great cost saving alternative to replacement. Your repaired product is returned with all necessary sub-assemblies and documentation. Your unit comes with a PDF Supply 2-year warranty. Request an RMA Free Ground delivery on all orders! Close User's Manual Free GroundThe quantity you tried to add to your cart is unavailable. So this website was intended for free download articles fromYou are self-liable for your download.You can learn how to disable cookie here. Cost-effective emergency spares and repairs, available with fast worldwide shipping. Contact us today for availability and pricing for GFK-1504 and PLC Systems. At NRwell our mission is to keep your business moving and to offer a superior level of service from people you can trust.http://www.kk-gorenjska.si/uporabnik/file/bosch-gst-85-pbe-manual.xml

NRwell will not pass your information to any other organisation and will process your information in accordance with our Brands, brand names and trademarks appearing on this website are the property of their respective owners. Diagnostics mode. Specifications. Number of modulesNetwork inputs per bus scanNetwork outputs per bus scanDiscrete Input MemoryDiscrete Output MemoryAnalog Input MemoryAnalog Output MemoryPower Consumption. Serial Bus AddressNetwork data rateKbaud standard, 76.8 Kbaud, orSee the TUV website forProduct Description. Firmware version:Genius NIU, the host controller must be one of the following. Firmware upgrades:Revision Letters:When a Genius NIU (all versions) is on a Genius bus controlled byController must have firmware version 5.4 or greater. UpgradingPLC must use one of the following CPU models:To use Enhanced Diagnostics mode in any GMR System, versionMay 8, 2009The IC200GBI001-HL replaces IC200GBI001-GK and previousVersion 3.20 firmware may be downloaded to any hardwareHowever, -Fx and earlier hardwareIC200GBI001 modules with firmware version 3.10 or earlier. Module faults for the VersaMax analog input modules. IC200ALG240, IC200ALG620 and IC200ALG630; the analog. Counter Module, IC200MDD841; and the Serial CommunicationsThis issue has been corrected in IC200GBI001 firmwareFor users who want newer GNIU firmware, a firmware upgrade kitVersaMax analog input modules IC200ALG240, IC200ALG620 andPrevious versions of analog input module firmware may produce. Product Revision History. RevJuly 2007. Hardware and firmware update. FirmwareGMR system. Firmware version 2.40. March 2007Improved Winloader compatibility.Changed to V0 plastic for moduleComponent changeATEX approval for Group 2 Category 3Firmware version 2.20. Added support for. High-Density Analog Modules.Firmware version 2.10Hardware changeRestrictions and Open IssuesFirmware version 2.30However, if theNIU does not restore Enhanced Diagnostics operation. The EDM. LED will be OFF.

Re-try the store of the new configuration, orFirmware version 1.50. Added support forFirmware version 1.10. Added support forMay 2009. Firmware release 3.20. November 2008 Firmware version 3.10Description. December 1998 Initial product release.Genius NIU station, and the GNIU is commanded to clear itsThis is not an issue when storingMay 8, 2009For the case of a GMR PLC, an operatorDiagnostics ModeIf a redundant VersaMax Input Station is available, the proceduresWhen used in the safety-relevant portion of a GMR system, the GNIU’s. Enhanced Diagnostics Mode must be enabled. Select whether toThe default is disabled. When. Enhanced Diagnostics Mode is enabled, the following requirementsMode is available in the Genius NIU User’s Manual.). System RequirementsConfiguration RequirementsThe GNIU's Report Faults parameter must be set to Enabled. InIt does not re-reportController. Genius NIU station’s status. Operating RequirementsDatagram COMMREQ. The application program must issue a. Read Configuration Datagram to determine the effectiveness of aForce BSM bit is accessible but must not be changed.Disconnect the GNIU from the Genius bus before attempting anyDiagnostics Mode set to Enabled either is currently installed or willAfter completing serial communications disconnect the serial cableThe GNIU can then be reattachedAn alternative to disconnecting the GNIU from the Genius bus is toThe loss of communications causes theGMR PLCs willIf the GNIU isGenius Bus Controller, the data lengths specified for %I, %Q, %AIQuick Start Guide. Preinstallation Check. Carefully inspect all shipping containers for damage. If any equipment isSave the damagedAfter unpackingSave the shipping containersThe procedureIf the Genius NIU hardware configuration is available:Configuration and select “Hardware Reference View”.The DIN rail must have a conductiveConnect the Windows PC running the programmingConfiguration and select “Hardware Reference View”.

Install the NIU on the DIN Rail by simply clicking it into place. Note: The NIU and connecting carriersIf the Genius NIU hardware configuration is NOT available:The latch on the power supply must beAlign the connectors and the latch postTurn the latch to the locked position toIf the GNIU attempts to come online with a configuration that hasAdditional faults present in the GNIU do not. Complete the power supply wiring as described in the installationThe descriptions of the operation of jumpers should have theSelect the baud rate to match that used by the other devicesKbaud extended, (2) 153.6 Kbaud standard, (1) 76.8 Kbaud,Cycle power to the NIU after changing the switch settings. May 8, 2009Connect the communications bus to the NIU. (Refer to theMain Bus. Connections. Redundant. ConnectionsThe NIU with power supply attached fitsNIU. Do not discard this cover; you will need to install it on theDo not remove the connector cover onInstallation in Hazardous Locations. Connector CoverWith power off, install additional modules by mountingThis equipment is suitable for use in CLASS I, DIVISION 2. GROUPS A, B, C, D or non-hazardous locations only. WARNING - EXPLOSION HAZARD - substitution ofWARNING - EXPLOSION HAZARD - Do not connect orPanel-Mounting. For best stability, the DIN rail should be installed on a panel usingIf excessive vibration is a factor the NIU should also be screwed down toAutoconfiguration then skipsRemoving the NIU from the DIN RailThe maximum exposed length of unshielded wires should be 5cm (2in). For added protection, each shield drain wire should be insulated withShield Out to Shield In of the next device. If the NIU is the firstIf it is the lastBoth wires shouldDo not mix stranded with solid wireTerminating the Bus. Terminating. Resistor. StartEndSerial 1. Serial 2. Shield In. Shield Out. Serial 1. If either bus will terminate at the NIU, connect a 75, 100, 120, or 150ohm terminating resistor across the Serial 1 and Serial 2 terminals.

TheIf ferrules are not used, twist each resistor leadSystem Bus Installation Guidelines. The serial bus can be treated as a Class 2 circuit when appropriateMaximum bus lengths may be affectedDo not mix cables of different impedance, regardless of cable run length. Other, smallsize twisted pair shielded wire of unspecified impedance can be used forSelection ofInstalling Suppression at the Communications LineFor an individual NIU, suppression canMOVs from Serial 1 and Serial 2 to the. Shield Out terminal. Suitable MOVsPanasonic ERZ-CO5FK221U, and. Siemens 505K140. Higher energyrated devices can also be used. Follow. GE Fanuc Versamax 1-919-535-3180 Modbus Master module for Versamax Genius NIU. Module supports one RS-485 serial port.To locate detailed information, check the Guide to the VersaMax Document Set below.It operates as a slave on the network. The Profibus Network Slave Module operates as a slave on the Profibus network. VersaMax PLC CPU power supply VersaMax Modules All VersaMax CPUs provide powerful PLC functionality.For information about the Ethernet Network Interface Unit, refer to the VersaMax System Ethernet Network Communications User’s Manual (GFK-1860). DeviceNet NIU The DeviceNet Network Interface Unit (IC200DBI001) is a DeviceNet slave module. For more information about a specific module, please refer to the Table of Contents or Index to locate the module description. Modules mount parallel to the DIN rail. If all the Expansion Receivers are the Isolated type (IC200ERM001), the maximum overall cable length is 750 meters. Some VersaMax analog modules require specific module revisions as listed below: Module Module Revision IC200ALG320 B or later IC200ALG321 B or later. Power for the communications module comes from the main system power supply or from a booster supply as shown below. VersaMax PLC CPU. After unpacking the VersaMax modules and other equipment, record all serial numbers.

Install the connector cover that was removed over the connector on the last carrier to protect the connector pins and to provide compliance with standards.Make sure rack power is off. Attach the Expansion Transmitter to DIN rail to the left of the CPU or NIU. Slide the module toward the CPU or NIU and press together until the connectors are mated. With a single-ended cable (one expansion rack only), set the Rack ID to 1. Install a VersaMax Power Supply module on top of the Expansion Receiver. See “Installing a Power Supply” in this chapter for details. If the expansion bus includes any non-isolated Expansion Receivers (IC200ERM002), the maximum overall cable length is 15 meters.The maximum cable length is one meter. Cables cannot be fabricated for this type of installation; cable IC200CBL600 must be ordered separately. Note: The VersaMax power supply is not hot-swappable. Hot inserting or extracting the power supply is an improper method to power-down or power-up. Hot inserting the power supply can cause a “Corrupted User Memory Fault”. Turn the latch to the unlocked position.These circuits may be rated from tens to thousands of KVA at 220 VAC or higher. Therefore, the AC source does not have to be grounded.For 120VAC nominal operation, install a jumper as marked on the power supply.Ground conductors should be connected in a star fashion, with all branches routed to a central earth ground point as shown below. This ensures that no ground conductor carries current from any other branch. When inserting two wires in the same position, the wires must be the same size and type (solid or stranded): Rigid or flexible wires: 0.2 to 1.5mm2 cross section. An example of such a module is the VersaMax 24VDC 16pt Output Module, IC200MDL740:. An example of such a module is the VersaMax 24VDC 16pt Input Module, IC200MDL640:. An example of an isolated. Voltage transients up to 300 VAC will not cause damage.Field Diagram 16 Point Module 32 Point Module Device Box-, Barrier-.

The latch on the module must be in the unlocked position as illustrated to install a module on its carrier. VersaMax equipment is suitable for use in non-hazardous locations or in Class 1, Div. 2, Groups A, B, C, and D, and Class 1 Zone 2 locations. See chapter 4 for information about the Power Supply Booster Carrier, which can be used to install an additional “booster” power supply in the system. IC200PWR001 24VDC Power Supply IC200PWR002 24VDC Expanded 3.3V Power Supply. Refer to the Power Supply Booster Carrier section of chapter 4 for more information.Refer to the Power Supply Booster Carrier section of chapter 4 for more information.Refer to the Power Supply Booster Carrier section of chapter 4 for more information.Refer to the Power Supply Booster Carrier section of chapter 4 for more information.The rail must have a conductive (unpainted) corrosion-resistant finish. For applications requiring maximum resistance to mechanical vibration and shock, the carrier must also be panel-mounted. The rail must have a conductive (unpainted) corrosion-resistant finish. For applications requiring maximum resistance to mechanical vibration and shock, the carrier must also be panel-mounted. During system operation, the card holder should be in the retracted position.Fast DIN-rail mounting. Can be located in any “slot”.For applications requiring maximum resistance to mechanical vibration and shock, the carrier must also be panel-mounted.Two groups of common terminals (W1-W8 and X1-X8) can be used for connecting two-wire devices without additional auxiliary terminal blocks. In addition, it has two groups of common terminals (Y1-Y8 and Z1- Z8) for connecting two-wire devices without additional auxiliary terminal blocks. Modules that are incompatible with these Interposing Disconnect Bases are indicated by shaded entries in the table. 1 Group. The Expansion Base, IC200CHS112, is for use with points 17-32 of the 32 point VersaMax module (IC200MDL750).

User loads must be powered by an external source. Each relay, status LED and fuse is labeled to indicate the specific point on the VersaMax output module they are associated with. Components labeled A1-A16 correspond to points Q1-Q16. The 16-pin male connector on the upper left side of the Expansion Transmitter is the pass-though serial programming port. The Expansion Transmitter connects to up to seven Expansion Receiver Modules in expansion “racks”. The. A VersaMax power supply installed on the Expansion Receiver Module provides operating power for the modules in the expansion rack. It is Off when not communicating. Expansion Rack Selection Switch The Rack Selection Switch is used to specify which expansion rack the ERM is in.Modules are connected using expansion cable IC200CBL6xx (xx represents the length in meters). A VersaMax power supply installed on the Expansion Receiver Module provides operating power for the modules in the expansion rack. Modules are connected using expansion cable IC200CBL6xx (xx represents the length in meters). This “single-ended” configuration has a maximum cable length of 1 meter. No terminator plug is required in the expansion rack. The green OK LED is on when backplane power is present to the module.Inputs are positive logic or sourcing-type inputs; they receive current from AC input devices and return the current on the common. Input devices are connected between the input terminals and common terminals. The green OK LED is on when backplane power is present to the module.Inputs are positive logic or sourcing-type inputs; they receive current from AC input devices and return the current on the common. Input devices are connected between the input terminals and common terminals. No thermal derating for these installations. No derating at 120VAC. Inputs are positive logic or sourcing-type inputs; they receive current from AC input devices and return the current on the common. Each input has its own return.No derating at 120VAC.

Deratings at 132VAC are shown below.Inputs are positive logic or sourcing-type inputs; they receive current from AC input devices and return the current on the common. Input devices are connected between the input terminals and common terminals. No derating for these installations. IC200MDL329 Output Module, 120VAC 0.5 Amp, Isolated 8 Points IC200MDL330 Output Module, 120VAC 0.5 Amp, Isolated 16 Points IC200MDL331 Output Module, 120VAC 2.0 Amp, Isolated 8 Points IC200MDL730 Output Module, 24VDC Positive Logic 2.0 Amps,. The output LEDs are logic-driven and independent of the load conditions. The green OK LED is on when backplane power is present to the module.The charts below show thermal deratings for the module at 120VAC with the maximum output current per point. The output LEDs are logic-driven and independent of the load conditions. The green OK LED is on when backplane power is present to the module.The charts below show thermal deratings for the module at 120VAC with the maximum output current per point. The output LEDs are logic-driven and independent of the load conditions.The charts below show thermal deratings for the module at 120VAC with the indicated output current per point. The outputs are positive or sourcing type outputs. They switch the loads to the positive side of the DC supply and thus supply current to the loads. 10 11 12 13 14 15 16 IC200MDL740 IND CONT EQ FOR HAZ LOC. Deratings at 30VDC shown below.Each point has electronic overcurrent protection and short circuit protection, and generates a fault if either condition exists. The outputs are positive or sourcing type outputs. Each point has electronic overcurrent protection and short circuit protection, and generates a fault if either condition exists. The outputs are positive or sourcing type outputs. The charts below show thermal deratings for the module at 24VDC and 30VDC with the maximum output current per point. The outputs are negative or sinking type outputs.

They switch the loads to the negative (return) side of the DC supply and thus receive current from the loads. 10 11 12 13 14 15 16 IC200MDL743 IND CONT EQ FOR HAZ LOC. Terminal Connection Terminal Connection Output 1 No connection Output 2 No connection Output 3 No connection Output 4 No connection.